【Delivery Example】Transfer of Cooling Water

Using a magnet pump type HT for cooling water circulation!

● Due to the failure of an overseas chiller, we received an order for an update of the cooling system. The chiller (made in Italy) used by the customer broke down, and since the repair would incur significant costs, they requested an update of the cooling system, including the chiller. The cooling water is used after the heating process when turning waste plastic into pellets, so overall temperature management and reliable pump transfer were required. ● Using a Magnet Pump HT type for cooling water circulation. The chiller was updated to a Hitachi model, and a Magnet Pump HTX-440 was used for the transfer from the PE cushion tank, the return from the heat exchanger, and the transfer to the cooling tower. It serves as the core of the system due to its durability and reliable transfer capabilities. Additionally, at the customer's request, to regularly maintain against resin pellet blockages, inline strainers were installed in various parts to improve maintainability.

  • 5.png
  • 6.png
  • 25.png
  • Other pumps

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

【Delivery Case】Transport of Urea Solution (Ad Blue)

Using a magnet pump HT type for transferring urea water (AdBlue)!

● Using HT type for urea water transfer With the upgrade of the specifications of the urea water transfer device that we have been using, we designed and manufactured the device in-house. It was particularly required to have high accuracy for the sale of urea water (AdBlue), and since a flow rate of over 200L/min was desired, we selected the magnetic pump HTX-441P and completed it as a compact device. To prevent erroneous detection of the flow meter due to air mixing, we devised the piping line and placed multi-joints in various locations for easy maintenance. A strainer was installed to prevent foreign matter contamination, as this is for the urea water used in truck SCR systems. We incorporated all the requests from the transportation company. ● Designed with consideration for installation on tank trucks, including vibration resistance and heat dissipation For use on tank trucks, we equipped the device with vibration-damping rubber to account for severe vibrations. To achieve stable operation even in harsh outdoor temperatures, we installed louvers near the magnetic pump. A recording device capable of issuing receipts is equipped on the right side of the front of the device. By turning the switch ON, it is possible to easily issue a receipt for the most recent flow rate.

  • 8.png
  • 6.png
  • 26.png
  • Other pumps

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録